Part Number Hot Search : 
7C1049 CR12R 250R180 11F04 3000L C6122F65 DF6109A SERIE
Product Description
Full Text Search
 

To Download CT2-B30L Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  time cube 84 b1201 www.turck.us ? 1-800-544-7769 ? fax: (763) 553-0708 ? turck inc. minneapolis, mn 55441 the modules ct 2 and ct 3 are electronic timers that are designed to be inserted beween a standard plug-in relay and its socket, enabling the relay to be operated as a timer relay. the ct modules are able to accept any standard 8 or 11-pin releco series c2 or c3 as well as those from any other supplier. the relay coil voltage must be in the range shown for each model. 8 and 11-pin, time cube ct 2a ct 3a off delay the timing starts when s is switched off. the relay drops out at time (t). r s s + ~ r s 2 10 (7) t function a ct 2b ct 3b blinker the relay blinks on/off at time (t) when switch s is closed. first pulse, on. (7) 10 s r ~ + s r t t t function b ct 2e ct 3e on delay the timing starts when the switch s is closed. the relay pulls in at the time (t). r s + ~ r s 2 10 (7) t function e ct 2-a30/s* .......9.5-18 v ct 2-a30/l ..........20-65 v ct 2-a30/m .......90-150 v ct 2-a30/u .....180-265 v ct 3-a30/s* .......9.5-18 v ct 3-a30/l ..........20-65 v ct 3-a30/m .......90-150 v ct 3-a30/u .....180-265 v ct 2-b30/s* ........ 9.5-18 v ct 2-b30/l ........... 20-65 v ct 2-b30/h ........ 90-265 v ct 3-b30/s* ........ 9.5-18 v ct 3-b30/l ........... 20-65 v ct 3-b30/h ........ 90-265 v ct 2-e30/s* ........ 9.5-18 v ct 2-e30/l ........... 20-65 v ct 2-e30/h ........ 90-265 v ct 3-e30/s* ........ 9.5-18 v ct 3-e30/l ........... 20-65 v ct 3-e30/h ........ 90-265 v ct2... (8-pin) and ct3... (11-pin) types with time range from 0.2 seconds to 30 minutes (range 30) *all types are for ac/dc except ? voltage range (only dc) specifications time accuracy repetition +0.5%/20 ms supply voltage 1 ms / volt. ambient temperature -0.25% / k reset time (types e, w, b) <150 ms reset time (types a, k) <200 ms triggering time: ac, 80 ms; dc, 50 ms ambient temperature -10? to +60? transient protection iec 255.4 housing material noryl se1 (ul94 v-1) protection class (din 40050) ip 40 weight avg. 35 g 35 50 12.5 24.5 10 9 8 7 6 1 2 3 4 5 1 9 3 2 1 8 7 6 5 4 1 0 1 time range setting dimensions 0.2-3 s 2-30 s 0.2-3 min 2-30 min range 30 dip - sw


▲Up To Search▲   

 
Price & Availability of CT2-B30L

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X